H02JCIRCUIT ARRANGEMENTS OR SYSTEMS FOR SUPPLYING OR DISTRIBUTING ELECTRIC POWERSYSTEMS FOR STORING ELECTRIC ENERGYThis subclass covers: ac or dc mains or distribution networks; circuit arrangements for battery supplies, including charging or control thereof, or coordinated supply from two or more sources of any kind;circuit arrangements or systems for wireless supply or distribution of electric power.This subclass does not cover: control of a single motor, generator or dynamo-electric converter, of the types covered by subclass H01F or H02K, which is covered by subclass H02P;control of a single motor or generator, of the types covered by subclass H02N, which is covered by that subclass.In this subclass non-limiting references (in the sense of paragraph 39 of the Guide to the IPC) may still be displayed in the scheme. H02J1/00 H02J1/00Circuit arrangements for dc mains or dc distribution networksGroup H02J1/00 is incomplete pending reclassification of documents from group H02J13/0003.
Group H02J1/00 is also impacted by reclassification into group H02J1/001.
Groups H02J13/0003, H02J1/00, and H02J1/001 should be considered in order to perform a complete search.
H02J1/001Hot plugging or unplugging of load or power modules to or from power distribution networksGroup H02J1/001 is incomplete pending reclassification of documents from groups H02J1/00 and H02J13/0003.
Groups H02J1/00, H02J13/0003, and H02J1/001 should be considered in order to perform a complete search.
H02J1/002Intermediate AC, e.g. DC supply with intermediated AC distributionGroup H02J1/002 is incomplete pending reclassification of documents from group H02J13/0003.
Groups H02J13/0003 and H02J1/002 should be considered in order to perform a complete search.
H02J1/02Arrangements for reducing harmonics or ripplesGroup H02J1/02 is incomplete pending reclassification of documents from group H02J13/0003.
Groups H02J13/0003 and H02J1/02 should be considered in order to perform a complete search.
H02J1/04Constant-current supply systemsGroup H02J1/04 is incomplete pending reclassification of documents from group H02J13/0003.
Groups H02J13/0003 and H02J1/04 should be considered in order to perform a complete search.
H02J1/06Two-wire systemsGroup H02J1/06 is incomplete pending reclassification of documents from group H02J13/0003.
Groups H02J13/0003 and H02J1/06 should be considered in order to perform a complete search.
H02J1/08Three-wire systemsSystems having more than three wiresGroup H02J1/08 is incomplete pending reclassification of documents from group H02J13/0003.
Groups H02J13/0003 and H02J1/08 should be considered in order to perform a complete search.
H02J1/082Plural DC voltage, e.g. DC supply voltage with at least two different DC voltage levelsGroup H02J1/082 is incomplete pending reclassification of documents from group H02J13/0003.
Groups H02J13/0003 and H02J1/082 should be considered in order to perform a complete search.
H02J1/084for selectively connecting the load or loads to one or several among a plurality of power lines or power sourcesGroup H02J1/084 is incomplete pending reclassification of documents from group H02J13/0003.
Groups H02J13/0003 and H02J1/084 should be considered in order to perform a complete search.
H02J1/086for providing alternative feeding paths between load or loads and source or sources when the main path failsGroup H02J1/086 is incomplete pending reclassification of documents from group H02J13/0003.
Groups H02J13/0003 and H02J1/086 should be considered in order to perform a complete search.
H02J1/10Parallel operation of dc sourcesGroup H02J1/10 is incomplete pending reclassification of documents from groups H02J2001/104 and H02J13/0003.
Groups H02J2001/104, H02J13/0003, and H02J1/10 should be considered in order to perform a complete search.
H02J1/102being switching converters H02J1/108, H02J1/12 take precedenceGroup H02J1/102 is incomplete pending reclassification of documents from groups H02J2001/104 and H02J13/0003.
Groups H02J2001/104, H02J13/0003, and H02J1/102 should be considered in order to perform a complete search.
H02J2001/104for synchronisationGroup H02J2001/104 is no longer used for the classification of documents as of 2020-01-01.
The content of this group is being reclassified into groups H02J1/10, H02J1/102, H02J1/106, H02J1/108, H02J1/109, H02J1/12, and H02J1/122.
Groups H02J2001/104, H02J1/10, H02J1/102, H02J1/106, H02J1/108, H02J1/109, H02J1/12, and H02J1/122 should be considered in order to perform a complete search.
H02J1/106for load balancing, symmetrisation, or sharingGroup H02J1/106 is incomplete pending reclassification of documents from groups H02J2001/104 and H02J13/0003.
Groups H02J2001/104, H02J13/0003, and H02J1/106 should be considered in order to perform a complete search.
H02J1/108using diodes blocking reverse current flow H02J1/12 takes precedenceGroup H02J1/108 is incomplete pending reclassification of documents from groups H02J2001/104 and H02J13/0003.
Groups H02J2001/104, H02J13/0003, and H02J1/108 should be considered in order to perform a complete search.
H02J1/109Scheduling or re-scheduling the operation of the DC sources in a particular order, e.g. connecting or disconnecting the sources in sequential, alternating or in subsets, to meet a given demandGroup H02J1/109 is incomplete pending reclassification of documents from groups H02J2001/104 and H02J13/0003.
Groups H02J2001/104, H02J13/0003, and H02J1/109 should be considered in order to perform a complete search.
H02J1/12Parallel operation of dc generators with converters, e.g. with mercury-arc rectifierGroup H02J1/12 is incomplete pending reclassification of documents from groups H02J2001/104 and H02J13/0003.
Groups H02J2001/104, H02J13/0003, and H02J1/12 should be considered in order to perform a complete search.
H02J1/122Provisions for temporary connection of DC sources of essentially the same voltage, e.g. jumpstart cablesGroup H02J1/122 is incomplete pending reclassification of documents from groups H02J2001/104 and H02J13/0003.
Groups H02J2001/104, H02J13/0003, and H02J1/122 should be considered in order to perform a complete search.
H02J1/14Balancing the load in a networkGroup H02J1/14 is incomplete pending reclassification of documents from group H02J13/0003.
Groups H02J13/0003 and H02J1/14 should be considered in order to perform a complete search.
H02J1/16using dynamo-electric machines coupled to flywheelsGroup H02J1/16 is incomplete pending reclassification of documents from group H02J13/0003.
Groups H02J13/0003 and H02J1/16 should be considered in order to perform a complete search.
H02J3/00Circuit arrangements for ac mains or ac distribution networksGroup H02J3/00 is incomplete pending reclassification of documents from group H02J13/0006.
Groups H02J13/0006 and H02J3/00 should be considered in order to perform a complete search.
H02J3/001Methods to deal with contingencies, e.g. abnormalities, faults or failuresGroup H02J3/001 is impacted by reclassification into groups H02J3/0012 and H02J3/00125.
Groups H02J3/001, H02J3/0012, and H02J3/00125 should be considered in order to perform a complete search.
H02J3/0012Contingency detectionGroup H02J3/0012 is incomplete pending reclassification of documents from groups H02J3/001 and H02J13/0006.
Groups H02J3/001, H02J13/0006, and H02J3/0012 should be considered in order to perform a complete search.
H02J3/00125Transmission line or load transient problems, e.g. overvoltage, resonance or self-excitation of inductive loads H02J3/01 takes precedenceGroup H02J3/00125 is incomplete pending reclassification of documents from groups H02J3/001 and H02J13/0006.
Groups H02J3/001, H02J13/0006, and H02J3/00125 should be considered in order to perform a complete search.
H02J3/002Flicker reduction, e.g. compensation of flicker introduced by non-linear loadGroup H02J3/002 is incomplete pending reclassification of documents from group H02J13/0006.
Groups H02J13/0006 and H02J3/002 should be considered in order to perform a complete search.
H02J3/003Load forecast, e.g. methods or systems for forecasting future load demandGroup H02J3/003 is incomplete pending reclassification of documents from group H02J13/0006.
Groups H02J13/0006 and H02J3/003 should be considered in order to perform a complete search.
H02J3/004Generation forecast, e.g. methods or systems for forecasting future energy generationGroup H02J3/004 is incomplete pending reclassification of documents from group H02J13/0006.
Groups H02J13/0006 and H02J3/004 should be considered in order to perform a complete search.
H02J3/005Arrangements for selectively connecting the load to one among a plurality of power lines or power sources for providing uninterruptable power supply H02J9/00Group H02J3/005 is no longer used for the classification of documents as of 2020-01-01.
The content of this group is being reclassified into groups H02J3/007 and H02J3/0075.
Groups H02J3/005, H02J3/007, and H02J3/0075 should be considered in order to perform a complete search.
H02J3/007Arrangements for selectively connecting the load or loads to one or several among a plurality of power lines or power sources for providing uninterruptable power supply H02J9/00Group H02J3/007 is incomplete pending reclassification of documents from groups H02J3/005 and H02J13/0006.
Groups H02J3/005, H02J13/0006, and H02J3/007 should be considered in order to perform a complete search.
H02J3/0073for providing alternative feeding paths between load and source when the main path fails, e.g. transformers, busbarsGroup H02J3/0073 is incomplete pending reclassification of documents from group H02J13/0006.
Groups H02J13/0006 and H02J3/0073 should be considered in order to perform a complete search.
H02J3/0075for providing alternative feeding paths between load and source according to economic or energy efficiency considerations, e.g. economic dispatchGroup H02J3/0075 is incomplete pending reclassification of documents from groups H02J3/005 and H02J13/0006.
Groups H02J3/005, H02J13/0006, and H02J3/0075 should be considered in order to perform a complete search.
H02J3/008involving trading of energy or energy transmission rightsGroup H02J3/008 is incomplete pending reclassification of documents from group H02J13/0006.
Groups H02J13/0006 and H02J3/008 should be considered in order to perform a complete search.
H02J3/01Arrangements for reducing harmonics or ripplesGroup H02J3/01 is incomplete pending reclassification of documents from group H02J13/0006.
Groups H02J13/0006 and H02J3/01 should be considered in order to perform a complete search.
H02J3/02using a single network for simultaneous distribution of power at different frequenciesusing a single network for simultaneous distribution of ac power and of dc powerGroup H02J3/02 is incomplete pending reclassification of documents from groups H02J13/0006, H02J13/0093, and H02J13/0096.
Groups H02J3/02, H02J13/0006, H02J13/0093, and H02J13/0096 should be considered in order to perform a complete search.
H02J3/04for connecting networks of the same frequency but supplied from different sourcesGroup H02J3/04 is incomplete pending reclassification of documents from group H02J13/0006.
Groups H02J13/0006 and H02J3/04 should be considered in order to perform a complete search.
H02J3/06Controlling transfer of power between connected networksControlling sharing of load between connected networksGroup H02J3/06 is incomplete pending reclassification of documents from group H02J13/0006.
Groups H02J13/0006 and H02J3/06 should be considered in order to perform a complete search.
H02J3/08Synchronising of networksGroup H02J3/08 is incomplete pending reclassification of documents from group H02J13/0006.
Groups H02J13/0006 and H02J3/08 should be considered in order to perform a complete search.
H02J3/10Constant-current supply systemsGroup H02J3/10 is incomplete pending reclassification of documents from group H02J13/0006.
Groups H02J13/0006 and H02J3/10 should be considered in order to perform a complete search.
H02J3/12for adjusting voltage in ac networks by changing a characteristic of the network loadGroup H02J3/12 is incomplete pending reclassification of documents from group H02J13/0006.
Groups H02J13/0006 and H02J3/12 should be considered in order to perform a complete search.
H02J3/14by switching loads on to, or off from, network, e.g. progressively balanced loadingGroup H02J3/14 is incomplete pending reclassification of documents from group H02J13/0006.
Group H02J3/14 is also impacted by reclassification into group H02J3/144.
Groups H02J13/0006, H02J3/14, and H02J3/144 should be considered in order to perform a complete search.
H02J3/144Demand-response operation of the power transmission or distribution networkGroup H02J3/144 is incomplete pending reclassification of documents from groups H02J3/14 and H02J13/0006.
Groups H02J3/14, H02J13/0006, and H02J3/144 should be considered in order to perform a complete search.
H02J3/16by adjustment of reactive powerGroup H02J3/16 is incomplete pending reclassification of documents from group H02J13/0006.
Groups H02J13/0006 and H02J3/16 should be considered in order to perform a complete search.
H02J3/18Arrangements for adjusting, eliminating or compensating reactive power in networks for adjustment of voltage H02J3/16Group H02J3/18 is incomplete pending reclassification of documents from group H02J13/0006.
Groups H02J13/0006 and H02J3/18 should be considered in order to perform a complete search.
H02J3/1807using series compensatorsGroup H02J3/1807 is incomplete pending reclassification of documents from group H02J13/0006.
Groups H02J13/0006 and H02J3/1807 should be considered in order to perform a complete search.
H02J3/1814wherein al least one reactive element is actively controlled by a bridge converter, e.g. unified power flow controllers [UPFC]Group H02J3/1814 is incomplete pending reclassification of documents from group H02J13/0006.
Groups H02J13/0006 and H02J3/1814 should be considered in order to perform a complete search.
H02J3/1821using shunt compensators H02J3/1807, H02J3/1878 take precedenceGroup H02J3/1821 is incomplete pending reclassification of documents from group H02J13/0006.
Groups H02J13/0006 and H02J3/1821 should be considered in order to perform a complete search.
H02J3/1828with stepwise control, the possibility of switching in or out the entire compensating arrangement not being considered as stepwise controlGroup H02J3/1828 is incomplete pending reclassification of documents from group H02J13/0006.
Groups H02J13/0006 and H02J3/1828 should be considered in order to perform a complete search.
H02J3/1835with stepless controlGroup H02J3/1835 is incomplete pending reclassification of documents from group H02J13/0006.
Groups H02J13/0006 and H02J3/1835 should be considered in order to perform a complete search.
H02J3/1842wherein at least one reactive element is actively controlled by a bridge converter, e.g. active filtersGroup H02J3/1842 is incomplete pending reclassification of documents from group H02J13/0006.
Groups H02J13/0006 and H02J3/1842 should be considered in order to perform a complete search.
H02J3/185wherein such reactive element is purely inductive, e.g. superconductive magnetic energy storage systems [SMES]Group H02J3/185 is incomplete pending reclassification of documents from group H02J13/0006.
Groups H02J13/0006 and H02J3/185 should be considered in order to perform a complete search.
H02J3/1857wherein such bridge converter is a multilevel converterGroup H02J3/1857 is incomplete pending reclassification of documents from group H02J13/0006.
Groups H02J13/0006 and H02J3/1857 should be considered in order to perform a complete search.
H02J3/1864wherein the stepless control of reactive power is obtained by at least one reactive element connected in series with a semiconductor switchGroup H02J3/1864 is incomplete pending reclassification of documents from group H02J13/0006.
Groups H02J13/0006 and H02J3/1864 should be considered in order to perform a complete search.
H02J3/1871Methods for planning installation of shunt reactive power compensatorsGroup H02J3/1871 is incomplete pending reclassification of documents from group H02J13/0006.
Groups H02J13/0006 and H02J3/1871 should be considered in order to perform a complete search.
H02J3/1878using tap changing or phase shifting transformersGroup H02J3/1878 is incomplete pending reclassification of documents from group H02J13/0006.
Groups H02J13/0006 and H02J3/1878 should be considered in order to perform a complete search.
H02J3/1885using rotating means, e.g. synchronous generatorsGroup H02J3/1885 is incomplete pending reclassification of documents from group H02J13/0006.
Groups H02J13/0006 and H02J3/1885 should be considered in order to perform a complete search.
H02J3/1892the arrangements being an integral part of the load, e.g. a motor, or of its control circuitGroup H02J3/1892 is incomplete pending reclassification of documents from group H02J13/0006.
Groups H02J13/0006 and H02J3/1892 should be considered in order to perform a complete search.
H02J3/20in long overhead linesGroup H02J3/20 is incomplete pending reclassification of documents from group H02J13/0006.
Groups H02J13/0006 and H02J3/20 should be considered in order to perform a complete search.
H02J3/22in cablesGroup H02J3/22 is incomplete pending reclassification of documents from group H02J13/0006.
Groups H02J13/0006 and H02J3/22 should be considered in order to perform a complete search.
H02J3/24Arrangements for preventing or reducing oscillations of power in networks by control effected upon a single generator H02P9/00Group H02J3/24 is incomplete pending reclassification of documents from group H02J13/0006.
Group H02J3/24 is also impacted by reclassification into groups H02J3/241 and H02J3/242.
Groups H02J3/24, H02J13/0006, H02J3/241 and H02J3/242 should be considered in order to perform a complete search.
H02J3/241The oscillation concerning frequencyGroup H02J3/241 is incomplete pending reclassification of documents from groups H02J3/24 and H02J13/0006.
Groups H02J3/24, H02J13/0006, and H02J3/241 should be considered in order to perform a complete search.
H02J3/242using phasor measuring units [PMU] Group H02J3/242 is incomplete pending reclassification of documents from groups H02J3/24 and H02J13/0006.
Groups H02J3/24, H02J13/0006, and H02J3/242 should be considered in order to perform a complete search.
H02J3/26Arrangements for eliminating or reducing asymmetry in polyphase networksGroup H02J3/26 is incomplete pending reclassification of documents from group H02J13/0006.
Groups H02J13/0006 and H02J3/26 should be considered in order to perform a complete search.
H02J3/28Arrangements for balancing of the load in a network by storage of energyGroup H02J3/28 is incomplete pending reclassification of documents from group H02J13/0006.
Groups H02J13/0006 and H02J3/28 should be considered in order to perform a complete search.
H02J3/30using dynamo-electric machines coupled to flywheelsGroup H02J3/30 is incomplete pending reclassification of documents from group H02J13/0006.
Groups H02J13/0006 and H02J3/30 should be considered in order to perform a complete search.
H02J3/32using batteries with converting meansGroup H02J3/32 is incomplete pending reclassification of documents from group H02J13/0006.
Group H02J3/32 is also impacted by reclassification into group H02J3/322.
Groups H02J13/0006, H02J3/32, and H02J3/322 should be considered in order to perform a complete search.
H02J3/322the battery being on-board an electric or hybrid vehicle, e.g. vehicle to grid arrangements [V2G], power aggregation, use of the battery for network load balancing, coordinated or cooperative battery chargingGroup H02J3/322 is incomplete pending reclassification of documents from groups H02J3/32, H02J7/0027, and H02J13/0006.
Groups H02J3/322, H02J3/32, H02J7/0027, and H02J13/0006 should be considered in order to perform a complete search.
H02J3/34Arrangements for transfer of electric power between networks of substantially different frequencyGroup H02J3/34 is incomplete pending reclassification of documents from group H02J13/0006.
Groups H02J13/0006 and H02J3/34 should be considered in order to perform a complete search.
H02J3/36Arrangements for transfer of electric power between ac networks via a high-tension dc linkGroup H02J3/36 is incomplete pending reclassification of documents from group H02J13/0006.
Groups H02J13/0006 and H02J3/36 should be considered in order to perform a complete search.
H02J2003/365Reducing harmonics or oscillations in HVDC
H02J3/38Arrangements for parallely feeding a single network by two or more generators, converters or transformersGroup H02J3/38 is incomplete pending reclassification of documents from group H02J13/0006.
Groups H02J13/0006 and H02J3/38 should be considered in order to perform a complete search.
H02J3/381Dispersed generatorsGroup H02J3/381 is incomplete pending reclassification of documents from group H02J13/0006.
Groups H02J13/0006 and H02J3/381 should be considered in order to perform a complete search.
H02J3/382the generators exploiting renewable energyGroup H02J3/382 is no longer used for the classification of documents as of 2020-01-01.
The content of this group is being reclassified into groups H02J2300/20, H02J2300/22, H02J3/388, H02J3/40, H02J3/42, H02J3/44, H02J3/46, H02J3/466, H02J3/472, H02J3/48, and H02J3/50.
Groups H02J3/382, H02J2300/20, H02J2300/22, H02J3/388, H02J3/40, H02J3/42, H02J3/44, H02J3/46, H02J3/466, H02J3/472, H02J3/48, and H02J3/50 should be considered in order to perform a complete search.
H02J3/383Solar energy, e.g. photovoltaic energy generation of electric power by conversion of light H02SGroup H02J3/383 is no longer used for the classification of documents as of 2020-01-01.
The content of this group is being reclassified into groups H02J2300/24, H02J3/388, H02J3/40, H02J3/42, H02J3/44, H02J3/46, H02J3/466, H02J3/472, H02J3/48, and H02J3/50.
Groups H02J3/383, H02J2300/24, H02J3/388, H02J3/40, H02J3/42, H02J3/44, H02J3/46, H02J3/466, H02J3/472, H02J3/48, and H02J3/50 should be considered in order to perform a complete search.
H02J3/385Maximum power point tracking control for photovoltaic sourcesGroup H02J3/385 is no longer used for the classification of documents as of 2020-01-01.
The content of this group is being reclassified into groups H02J2300/26, H02J3/388, H02J3/40, H02J3/42, H02J3/44, H02J3/46, H02J3/466, H02J3/472, H02J3/48, and H02J3/50.
Groups H02J3/385, H02J2300/26, H02J3/388, H02J3/40, H02J3/42, H02J3/44, H02J3/46, H02J3/466, H02J3/472, H02J3/48, and H02J3/50 should be considered in order to perform a complete search.
H02J3/386Wind energy wind motors F03DGroup H02J3/386 is no longer used for the classification of documents as of 2020-01-01.
The content of this group is being reclassified into groups H02J2300/28, H02J3/388, H02J3/40, H02J3/42, H02J3/44, H02J3/46, H02J3/466, H02J3/472, H02J3/48, and H02J3/50.
Groups H02J3/386, H02J2300/28, H02J3/388, H02J3/40, H02J3/42, H02J3/44, H02J3/46, H02J3/466, H02J3/472, H02J3/48, and H02J3/50 should be considered in order to perform a complete search.
H02J3/387using fuel cells fuel cells per se H01M8/00Group H02J3/387 is no longer used for the classification of documents as of 2020-01-01.
The content of this group is being reclassified into groups H02J2300/30, H02J3/388, H02J3/40, H02J3/42, H02J3/44, H02J3/46, H02J3/466, H02J3/472, H02J3/48, and H02J3/50.
Groups H02J3/387, H02J2300/30, H02J3/388, H02J3/40, H02J3/42, H02J3/44, H02J3/46, H02J3/466, H02J3/472, H02J3/48, and H02J3/50 should be considered in order to perform a complete search.
H02J3/388Islanding, i.e. disconnection of local power supply from the networkGroup H02J3/388 is incomplete pending reclassification of documents from groups H02J3/382, H02J3/383, H02J3/385, H02J3/386, H02J3/387, and H02J13/0006.
Groups H02J3/388, H02J3/382, H02J3/383, H02J3/385, H02J3/386, H02J3/387, and H02J13/0006 should be considered in order to perform a complete search.
H02J3/40Synchronising a generator for connection to a network or to another generatorGroup H02J3/40 is incomplete pending reclassification of documents from groups H02J3/382, H02J3/383, H02J3/385, H02J3/386, H02J3/387, and H02J13/0006.
Groups H02J3/40, H02J3/382, H02J3/383, H02J3/385, H02J3/386, H02J3/387, and H02J13/0006 should be considered in order to perform a complete search.
H02J3/42with automatic parallel connection when synchronisation is achievedGroup H02J3/42 is incomplete pending reclassification of documents from groups H02J3/382, H02J3/383, H02J3/385, H02J3/386, H02J3/387, and H02J13/0006.
Groups H02J3/42, H02J3/382, H02J3/383, H02J3/385, H02J3/386, H02J3/387, and H02J13/0006 should be considered in order to perform a complete search.
H02J3/44with means for ensuring correct phase sequenceGroup H02J3/44 is incomplete pending reclassification of documents from groups H02J3/382, H02J3/383, H02J3/385, H02J3/386, H02J3/387, and H02J13/0006.
Groups H02J3/44, H02J3/382, H02J3/383, H02J3/385, H02J3/386, H02J3/387, and H02J13/0006 should be considered in order to perform a complete search.
H02J3/46Controlling of the sharing of output between the generators, converters, or transformersGroup H02J3/46 is incomplete pending reclassification of documents from groups H02J3/382, H02J3/383, H02J3/385, H02J3/386, H02J3/387, and H02J13/0006.
Group H02J3/46 is also impacted by reclassification into groups H02J3/466 and H02J3/472.
Groups H02J3/46, H02J3/382, H02J3/383, H02J3/385, H02J3/386, H02J3/387, H02J13/0006, H02J3/466 and H02J3/472 should be considered in order to perform a complete search.
H02J3/466Scheduling the operation of the generators, e.g. connecting or disconnecting generators to meet a given demandGroup H02J3/466 is incomplete pending reclassification of documents from groups H02J3/382, H02J3/383, H02J3/385, H02J3/386, H02J3/387, and H02J3/46.
Groups H02J3/466, H02J3/382, H02J3/383, H02J3/385, H02J3/386, H02J3/387, and H02J3/46 should be considered in order to perform a complete search.
H02J3/472For selectively connecting the AC sources in a particular order, e.g. sequential, alternating or subsets of sourcesGroup H02J3/472 is incomplete pending reclassification of documents from groups H02J3/382, H02J3/383, H02J3/385, H02J3/386, H02J3/387, H02J3/46, and H02J13/0006.
Groups H02J3/472, H02J3/382, H02J3/383, H02J3/385, H02J3/386, H02J3/387, H02J3/46, and H02J13/0006 should be considered in order to perform a complete search.
H02J3/48Controlling the sharing of the in-phase componentGroup H02J3/48 is incomplete pending reclassification of documents from groups H02J3/382, H02J3/383, H02J3/385, H02J3/386, H02J3/387, and H02J13/0006.
Groups H02J3/48, H02J3/382, H02J3/383, H02J3/385, H02J3/386, H02J3/387, and H02J13/0006 should be considered in order to perform a complete search.
H02J3/50Controlling the sharing of the out-of-phase componentGroup H02J3/50 is incomplete pending reclassification of documents from groups H02J3/382, H02J3/383, H02J3/385, H02J3/386, H02J3/387, and H02J13/0006.
Groups H02J3/50, H02J3/382, H02J3/383, H02J3/385, H02J3/386, H02J3/387, and H02J13/0006 should be considered in order to perform a complete search.
H02J4/00Circuit arrangements for mains or distribution networks not specified as ac or dcGroup H02J4/00 is incomplete pending reclassification of documents from group H02J13/0096.
Groups H02J13/0096 and H02J4/00 should be considered in order to perform a complete search.
H02J5/00Circuit arrangements for transfer of electric power between ac networks and dc networks H02J3/36 takes precedenceGroup H02J5/00 is incomplete pending reclassification of documents from group H02J5/005.
Groups H02J5/005 and H02J5/00 should be considered in order to perform a complete search.
H02J5/005with inductive power transfer for charging H02J7/025Group H02J5/005 is no longer used for the classification of documents as of 2020-01-01.
The content of this group is being reclassified into groups H02J5/00, H02J50/001, H02J50/005, H02J50/10, H02J50/12, H02J50/30, H02J50/40, H02J50/402, H02J50/50, H02J50/502, H02J50/60, H02J50/70, H02J50/80, and H02J50/90.
All groups listed in this Warning should be considered in order to perform a complete search.
H02J7/00Circuit arrangements for charging or depolarising batteries or for supplying loads from batteriesGroup H02J7/00 is incomplete pending reclassification of documents from groups H02J7/0077, H02J7/0085, H02J7/0088, and H02J7/025.
Groups H02J7/00, H02J7/0077, H02J7/0085, H02J7/0088, and H02J7/025 should be considered in order to perform a complete search.
H02J7/0003with provision for charging different types of batteriesGroup H02J7/0003 is no longer used for the classification of documents as of 2020-01-01.
The content of this group is being reclassified into groups H02J7/00032, H02J7/00034, H02J7/00045, and H02J7/00047.
Groups H02J7/0003, H02J7/00032, H02J7/00034, H02J7/00045, and H02J7/00047 should be considered in order to perform a complete search.
H02J7/00032characterised by data exchangeGroup H02J7/00032 is incomplete pending reclassification of documents from group H02J7/0003.
Groups H02J7/0003 and H02J7/00032 should be considered in order to perform a complete search.
H02J7/00034Charger exchanging data with an electronic device, i.e. telephone, whose internal battery is under chargeGroup H02J7/00034 is incomplete pending reclassification of documents from group H02J7/0003.
Groups H02J7/0003 and H02J7/00034 should be considered in order to perform a complete search.
H02J7/00036Charger exchanging data with battery H02J7/00038using passive battery identification means, e.g. resistors or capacitors identification by mechanical connections H02J7/0045 H02J7/00041in response to measured battery parameters, e.g. voltage, current or temperature profile H02J7/00043using switches, contacts or markings, e.g. optical, magnetic or barcode H02J7/00045Authentication, i.e. circuits for checking compatibility between one component, e.g. a battery or a battery charger, and another component, e.g. a power sourceGroup H02J7/00045 is incomplete pending reclassification of documents from group H02J7/0003.
Groups H02J7/0003 and H02J7/00045 should be considered in order to perform a complete search.
H02J7/00047with provisions for charging different types of batteriesGroup H02J7/00047 is incomplete pending reclassification of documents from group H02J7/0003.
Groups H02J7/0003 and H02J7/00047 should be considered in order to perform a complete search.
H02J7/0013acting upon several batteries simultaneously or sequentially H02J7/1423 takes precedenceGroup H02J7/0013 is incomplete pending reclassification of documents from groups H02J7/0021, H02J7/0022, and H02J7/0027.
Groups H02J7/0013, H02J7/0021, H02J7/0022, and H02J7/0027 should be considered in order to perform a complete search.
H02J7/0014Circuits for equalisation of charge between batteriesGroup H02J7/0014 is incomplete pending reclassification of documents from groups H02J7/0021, H02J7/0022, and H02J7/0027.
Groups H02J7/0014, H02J7/0021, H02J7/0022, and H02J7/0027 should be considered in order to perform a complete search.
H02J7/0016using shunting, discharge or bypass circuitsGroup H02J7/0016 is incomplete pending reclassification of documents from groups H02J7/0021, H02J7/0022, and H02J7/0027.
Groups H02J7/0016, H02J7/0021, H02J7/0022, and H02J7/0027 should be considered in order to perform a complete search.
H02J7/0018using separate charge circuitsGroup H02J7/0018 is incomplete pending reclassification of documents from groups H02J7/0021, H02J7/0022, and H02J7/0027.
Groups H02J7/0018, H02J7/0021, H02J7/0022, and H02J7/0027 should be considered in order to perform a complete search.
H02J7/0019using switched or multiplexed charge circuitsGroup H02J7/0019 is incomplete pending reclassification of documents from groups H02J7/0021, H02J7/0022, and H02J7/0027.
Groups H02J7/0019, H02J7/0021, H02J7/0022, and H02J7/0027 should be considered in order to perform a complete search.
H02J7/0021Monitoring or indicating circuits H02J7/0026 takes precedence Group H02J7/0021 is no longer used for the classification of documents as of 2020-01-01.
The content of this group is being reclassified into groups H02J7/0047, H02J7/0048, H02J7/0049, H02J7/005, H02J7/0013, H02J7/0014, H02J7/0016, H02J7/0018, H02J7/0019, H02J7/0024, and H02J7/0025.
All groups listed in this Warning should be considered in order to perform a complete search.
H02J7/0022Management of charging with batteries permanently connected to charge circuit H02J7/0014 takes precedenceGroup H02J7/0022 is no longer used for the classification of documents as of 2020-01-01.
The content of this group is being reclassified into groups H02J7/0013, H02J7/0014, H02J7/0016, H02J7/0018, H02J7/0019, H02J7/0024, and H02J7/0025.
All groups listed in this Warning should be considered in order to perform a complete search.
H02J7/0024Parallel/serial switching of connection of batteries to charge or load circuitGroup H02J7/0024 is incomplete pending reclassification of documents from groups H02J7/0021, H02J7/0022, and H02J7/0027.
Groups H02J7/0024, H02J7/0021, H02J7/0022, and H02J7/0027 should be considered in order to perform a complete search.
H02J7/0025Sequential battery discharge in systems with a plurality of batteriesGroup H02J7/0025 is incomplete pending reclassification of documents from groups H02J7/0021, H02J7/0022, H02J7/0027, H02J7/0063, and H02J2007/0067.
Groups H02J7/0025, H02J7/0021, H02J7/0022, H02J7/0027, H02J7/0063, and H02J2007/0067 should be considered in order to perform a complete search.
H02J7/0026using safety or protection circuits, e.g. overcharge/discharge disconnectionGroup H02J7/0026 is no longer used for the classification of documents as of 2020-01-01.
The content of this group is being reclassified into groups H02J7/0029, H02J7/00302, H02J7/00304, H02J7/00306, H02J7/00308, and H02J7/00309.
Groups H02J7/0026, H02J7/0029, H02J7/00302, H02J7/00304, H02J7/00306, H02J7/00308, and H02J7/00309 should be considered in order to perform a complete search.
H02J7/0027Stations for charging mobile units, e.g. of electric vehicles, of mobile telephones H02J7/0021, H02J7/0026 take precedenceGroup H02J7/0027 is no longer used for the classification of documents as of 2020-01-01.
The content of this group is being reclassified into groups H02J3/322, H02J7/0013, H02J7/0014, H02J7/0016, H02J7/0018, H02J7/0019, H02J7/0024, H02J7/0025, H02J7/0042, H02J7/0044, H02J7/0045, H02J2310/22, H02J2310/40, H02J2310/42, H02J2310/44, H02J2310/46, and H02J2310/48.
All groups listed in this Warning should be considered in order to perform a complete search.
H02J7/0029with safety or protection devices or circuitsGroup H02J7/0029 is incomplete pending reclassification of documents from groups H02J7/0026, H02J7/027, H02J7/1461, and H02J7/166.
Group H02J7/0029 is also impacted by reclassification into groups H02J7/00302, H02J7/00304, H02J7/00306, H02J7/00308, and H02J7/00309.
Groups H02J7/0029, H02J7/0026, H02J7/027, H02J7/1461, and H02J7/166, H02J7/00302, H02J7/00304, H02J7/00306, H02J7/00308, and H02J7/00309 should be considered in order to perform a complete search.
H02J7/00302Overcharge protectionGroup H02J7/00302 is incomplete pending reclassification of documents from groups H02J7/0026, H02J7/0029, H02J7/027, H02J7/1461, and H02J7/166.
Groups H02J7/00302, H02J7/0026, H02J7/0029, H02J7/027, H02J7/1461, and H02J7/166 should be considered in order to perform a complete search.
H02J7/00304Overcurrent protectionGroup H02J7/00304 is incomplete pending reclassification of documents from groups H02J7/0026, H02J7/0029, H02J7/027, H02J7/1461, and H02J7/166.
Groups H02J7/00304, H02J7/0026, H02J7/0029, H02J7/027, H02J7/1461, and H02J7/166 should be considered in order to perform a complete search.
H02J7/00306Overdischarge protectionGroup H02J7/00306 is incomplete pending reclassification of documents from groups H02J7/0026, H02J7/0029, H02J7/027, H02J7/1461, and H02J7/166.
Groups H02J7/00306, H02J7/0026, H02J7/0029, H02J7/027, H02J7/1461, and H02J7/166 should be considered in order to perform a complete search.
H02J7/00308Overvoltage protectionGroup H02J7/00308 is incomplete pending reclassification of documents from groups H02J7/0026, H02J7/0029, H02J7/027, H02J7/1461, and H02J7/166.
Groups H02J7/00308, H02J7/0026, H02J7/0029, H02J7/027, H02J7/1461, and H02J7/166 should be considered in order to perform a complete search.
H02J7/00309Overheat or overtemperature protectionGroup H02J7/00309 is incomplete pending reclassification of documents from groups H02J7/0026, H02J7/0029, H02J7/027, H02J7/1461, and H02J7/166.
Groups H02J7/00309, H02J7/0026, H02J7/0029, H02J7/027, H02J7/1461, and H02J7/166 should be considered in order to perform a complete search.
H02J7/0031using battery or load disconnect circuits H02J9/002 takes precedence H02J7/0032disconnection of loads if battery is not under charge, e.g. in vehicle if engine is not running H02J7/0034using reverse polarity correcting or protecting circuits mechanical means of polarity protection H02J7/0045 H02J7/0036using connection detecting circuits H02J7/0034 takes precedence
H02J7/0042characterised by the mechanical constructionGroup H02J7/0042 is incomplete pending reclassification of documents from groups H02J7/0027 and H02J7/025.
Groups H02J7/0027, H02J7/025, and H02J7/0042 should be considered in order to perform a complete search.
H02J7/0044specially adapted for holding portable devices containing batteries H02J7/0045 takes precedenceGroup H02J7/0044 is incomplete pending reclassification of documents from groups H02J7/0027 and H02J7/025.
Groups H02J7/0027, H02J7/025, and H02J7/0044 should be considered in order to perform a complete search.
H02J7/0045concerning the insertion or the connection of the batteriesGroup H02J7/0045 is incomplete pending reclassification of documents from groups H02J7/0027 and H02J7/025.
Groups H02J7/0027, H02J7/025, and H02J7/0045 should be considered in order to perform a complete search.
H02J7/0047with monitoring or indicating devices or circuitsGroup H02J7/0047 is incomplete pending reclassification of documents from groups H02J7/0021, H02J7/027, H02J7/1461, and H02J7/166.
Group H02J7/0047 is also impacted by reclassification into groups H02J7/0048 and H02J7/005.
Groups H02J7/0047, H02J7/0021, H02J7/027, H02J7/1461, and H02J7/166 should be considered in order to perform a complete search.
H02J7/0048Detection of remaining charge capacity or state of charge [SOC]Group H02J7/0048 is incomplete pending reclassification of documents from groups H02J7/0021, H02J7/0047, H02J7/027, H02J7/1461, and H02J7/166.
Groups H02J7/0048, H02J7/0021, H02J7/0047, H02J7/027, H02J7/1461, and H02J7/166 should be considered in order to perform a complete search.
H02J7/0049Detection of fully charged conditionGroup H02J7/0049 is incomplete pending reclassification of documents from groups H02J7/0021, H02J7/027, H02J7/1461, and H02J7/166.
Groups H02J7/0049, H02J7/0021, H02J7/027, H02J7/1461, and H02J7/166 should be considered in order to perform a complete search.
H02J7/005Detection of state of health [SOH]Group H02J7/005 is incomplete pending reclassification of documents from groups H02J7/0021, H02J7/0047, H02J7/027, H02J7/1461, and H02J7/166.
Groups H02J7/005, H02J7/0021, H02J7/0047, H02J7/027, H02J7/1461, and H02J7/166 should be considered in order to perform a complete search.
H02J7/0063with circuits adapted for supplying loads from the batteryGroup H02J7/0063 is impacted by reclassification into groups H02J7/0025, H02J7/007, H02J7/0071, H02J7/00711, H02J7/00712, H02J7/00714, H02J7/00716, H02J7/00718, H02J7/007182, H02J7/007184, H02J7/007186, H02J7/007188, H02J7/00719, H02J7/007192, and H02J7/007194.
All groups listed in this Warning should be considered in order to perform a complete search.
H02J2007/0067Discharge management, i.e. discharge current reduction at low state of charge, sequential battery discharge in systems with a plurality of batteryGroup H02J2007/0067 is no longer used for the classification of documents as of 2020-01-01.
The content of this group is being reclassified into groups H02J7/0025, H02J7/007, H02J7/0071, H02J7/00711, H02J7/00712, H02J7/00714, H02J7/00716, H02J7/00718, H02J7/007182, H02J7/007184, H02J7/007186, H02J7/007188, H02J7/00719, H02J7/007192, and H02J7/007194.
All groups listed in this Warning should be considered in order to perform a complete search.
H02J7/0068Battery or charger load switching, e.g. concurrent charging and load supply H02J7/0013 takes precedence H02J7/0069Charging or discharging for charge maintenance, battery initiation or rejuvenation H02J7/007Regulation of charging or discharging current or voltageGroup H02J7/007 is incomplete pending reclassification of documents from groups H02J7/0063, H02J2007/0067, H02J7/042, H02J2007/10, and H02J7/125.
Group H02J7/007 is also impacted by reclassification into groups H02J7/00712 and H02J7/007188.
All groups listed in this Warning should be considered in order to perform a complete search.
H02J7/0071with a programmable scheduleGroup H02J7/0071 is incomplete pending reclassification of documents from groups H02J7/0063, H02J2007/0067, H02J7/0072, H02J7/042, H02J2007/10, and H02J7/125.
Groups H02J7/0071, H02J7/0063, H02J2007/0067, H02J7/0072, H02J7/042, H02J2007/10, and H02J7/125 should be considered in order to perform a complete search.
H02J7/00711with introduction of pulses during the charging processGroup H02J7/00711 is incomplete pending reclassification of documents from groups H02J7/0063, H02J2007/0067, H02J7/0072, H02J7/042, H02J2007/10, and H02J7/125.
All groups listed in this Warning should be considered in order to perform a complete search.
H02J7/00712the cycle being controlled or terminated in response to electric parametersGroup H02J7/00712 is incomplete pending reclassification of documents from groups H02J7/0063, H02J2007/0067, H02J7/007, H02J7/0077, H02J7/008, H02J7/042, H02J7/085, H02J2007/10, and H02J7/125.
All groups listed in this Warning should be considered in order to perform a complete search.
H02J7/00714in response to battery charging or discharging currentGroup H02J7/00714 is incomplete pending reclassification of documents from groups H02J7/0063, H02J2007/0067, H02J7/0072, H02J7/0078, H02J7/008, H02J7/042, H02J7/045, H02J7/085, H02J2007/10, and H02J7/125.
All groups listed in this Warning should be considered in order to perform a complete search.
H02J7/00716in response to integrated charge or discharge currentGroup H02J7/00716 is incomplete pending reclassification of documents from groups H02J7/0063, H02J2007/0067, H02J7/0072, H02J7/0078, H02J7/008, H02J7/042, H02J7/085, H02J2007/10, and H02J7/125.
All groups listed in this Warning should be considered in order to perform a complete search.
H02J7/00718in response to charge current gradientGroup H02J7/00718 is incomplete pending reclassification of documents from groups H02J7/0063, H02J2007/0067, H02J7/0072, H02J7/0078, H02J7/008, H02J7/042, H02J7/045, H02J7/085, H02J2007/10, and H02J7/125.
All groups listed in this Warning should be considered in order to perform a complete search.
H02J7/007182in response to battery voltageGroup H02J7/007182 is incomplete pending reclassification of documents from groups H02J7/0063, H02J2007/0067, H02J7/0072, H02J7/008, H02J7/0086, H02J7/042, H02J7/045, H02J7/085, H02J2007/10, and H02J7/125.
All groups listed in this Warning should be considered in order to perform a complete search.
H02J7/007184in response to battery voltage gradientGroup H02J7/007184 is incomplete pending reclassification of documents from groups H02J7/0063, H02J2007/0067, H02J7/0072, H02J7/008, H02J7/0086, H02J7/042, H02J7/045, H02J7/085, H02J2007/10, and H02J7/125.
All groups listed in this Warning should be considered in order to perform a complete search.
H02J7/007186obtained with the battery disconnected from the charge or discharge circuitGroup H02J7/007186 is incomplete pending reclassification of documents from groups H02J7/0063, H02J2007/0067, H02J7/0072, H02J7/0085, H02J7/042, H02J7/045, H02J7/085, H02J2007/10, and H02J7/125.
All groups listed in this Warning should be considered in order to perform a complete search.
H02J7/007188the charge cycle being controlled or terminated in response to non-electric parametersGroup H02J7/007188 is incomplete pending reclassification of documents from groups H02J7/0063, H02J2007/0067, H02J7/007, H02J7/0072, H02J7/0088, H02J7/042, H02J7/087, H02J2007/10, and H02J7/125.
All groups listed in this Warning should be considered in order to perform a complete search.
H02J7/00719in response to degree of gas development in the batteryGroup H02J7/00719 is incomplete pending reclassification of documents from groups H02J7/0063, H02J2007/0067, H02J7/0072, H02J7/042, H02J7/087, H02J2007/10, and H02J7/125.
All groups listed in this Warning should be considered in order to perform a complete search.
H02J7/007192in response to temperatureGroup H02J7/007192 is incomplete pending reclassification of documents from groups H02J7/0063, H02J2007/0067, H02J7/0072, H02J7/0091, H02J7/042, H02J7/087, H02J2007/10, and H02J7/125.
Group H02J7/007192 is also impacted by reclassification into group H02J7/007194.
All groups listed in this Warning should be considered in order to perform a complete search.
H02J7/007194of the batteryGroup H02J7/007194 is incomplete pending reclassification of documents from groups H02J7/0063, H02J2007/0067, H02J7/007192, H02J7/0072, H02J7/0091, H02J7/042, H02J7/087, H02J2007/10, and H02J7/125.
All groups listed in this Warning should be considered in order to perform a complete search.
H02J7/0072using semiconductor devices onlyGroup H02J7/0072 is no longer used for the classification of documents as of 2020-01-01.
The content of this group is being reclassified into groups H02J7/0071, H02J7/00711, H02J7/00714, H02J7/00716, H02J7/00718, H02J7/007182, H02J7/007184, H02J7/007186, H02J7/007188, H02J7/00719, H02J7/007192, and H02J7/007194.
All groups listed in this Warning should be considered in order to perform a complete search.
H02J7/0077the charge cycle being terminated in response to electric parameters H02J7/0093 takes precedenceGroup H02J7/0077 is no longer used for the classification of documents as of 2020-01-01.
The content of this group is being reclassified into groups H02J7/00 and H02J7/00712.
Groups H02J7/0077, H02J7/00, and H02J7/00712 should be considered in order to perform a complete search.
H02J7/0078in response to discharge current, e.g. using a coulometer, pilot cellGroup H02J7/0078 is no longer used for the classification of documents as of 2020-01-01.
The content of this group is being reclassified into groups H02J7/00714, H02J7/00716, and H02J7/00718.
Groups H02J7/0078, H02J7/00714, H02J7/00716, and H02J7/00718 should be considered in order to perform a complete search.
H02J7/008with the battery connected to the charge circuitGroup H02J7/008 is no longer used for the classification of documents as of 2020-01-01.
The content of this group is being reclassified into groups H02J7/00712, H02J7/00714, H02J7/00716, H02J7/00718, H02J7/007182, and H02J7/007184.
All groups listed in this Warning should be considered in order to perform a complete search.
H02J7/0085with the battery disconnected from the charge circuitGroup H02J7/0085 is no longer used for the classification of documents as of 2020-01-01.
The content of this group is being reclassified into groups H02J7/00 and H02J7/007186.
Groups H02J7/0085, H02J7/00, and H02J7/007186 should be considered in order to perform a complete search.
H02J7/0086and in response to battery voltageGroup H02J7/0086 is no longer used for the classification of documents as of 2020-01-01.
The content of this group is being reclassified into groups H02J7/007182 and H02J7/007184.
Groups H02J7/0086, H02J7/007182, and H02J7/007184 should be considered in order to perform a complete search.
H02J7/0088the charge cycle being terminated in response to non-electric parameters H02J7/0093 takes precedenceGroup H02J7/0088 is no longer used for the classification of documents as of 2020-01-01.
The content of this group is being reclassified into groups H02J7/00 and H02J7/007188.
Groups H02J7/0088, H02J7/00, and H02J7/007188 should be considered in order to perform a complete search.
H02J7/0091in response to temperature of the batteryGroup H02J7/0091 is no longer used for the classification of documents as of 2020-01-01.
The content of this group is being reclassified into groups H02J7/007192 and H02J7/007194.
Groups H02J7/0091, H02J7/007192, and H02J7/007194 should be considered in order to perform a complete search.
H02J7/02for charging batteries from ac mains by convertersGroup H02J7/02 is incomplete pending reclassification of documents from group H02J7/022.
Groups H02J7/022 and H02J7/02 should be considered in order to perform a complete search.
H02J7/022characterised by the type of converterGroup H02J7/022 is no longer used for the classification of documents as of 2020-01-01.
The content of this group is being reclassified into groups H02J7/02 and H02J2207/20.
Groups H02J7/022, H02J7/02, and H02J2207/20 should be considered in order to perform a complete search.
H02J7/025using non-contact coupling, e.g. inductive, capacitiveGroup H02J7/025 is no longer used for the classification of documents as of 2020-01-01.
The content of this group is being reclassified into groups H02J50/001, H02J50/005, H02J50/10, H02J50/12, H02J50/30, H02J50/40, H02J50/402, H02J50/50, H02J50/502, H02J50/60, H02J50/70, H02J50/80, H02J50/90, H02J7/00, H02J7/0042, H02J7/0044, and H02J7/0045.
All groups listed in this Warning should be considered in order to perform a complete search.
H02J7/027with safety or indicating deviceGroup H02J7/027 is no longer used for the classification of documents as of 2020-01-01.
The content of this group is being reclassified into groups H02J7/0029, H02J7/00302, H02J7/00304, H02J7/00306, H02J7/00308, H02J7/00309, H02J7/0047, H02J7/0048, H02J7/0049, and H02J7/005.
All groups listed in this Warning should be considered in order to perform a complete search.
H02J7/04Regulation of charging current or voltage H02J7/042the charge cycle being controlled in response to a measured parameterGroup H02J7/042 is no longer used for the classification of documents as of 2020-01-01.
The content of this group is being reclassified into groups H02J7/007, H02J7/0071, H02J7/00711, H02J7/00712, H02J7/00714, H02J7/00716, H02J7/00718, H02J7/007182, H02J7/007184, H02J7/007186, H02J7/007188, H02J7/00719, H02J7/007192, and H02J7/007194.
All groups listed in this Warning should be considered in order to perform a complete search.
H02J7/045in response to voltage or current Group H02J7/045 is no longer used for the classification of documents as of 2020-01-01.
The content of this group is being reclassified into groups H02J7/00714, H02J7/00718, H02J7/007182, H02J7/007184, and H02J7/007186.
All groups listed in this Warning should be considered in order to perform a complete search.
H02J7/06using discharge tubes or semiconductor devices H02J7/08using discharge tubes only H02J7/085the charge cycle being terminated in response to electric parametersGroup H02J7/085 is no longer used for the classification of documents as of 2020-01-01.
The content of this group is being reclassified into groups H02J7/00712, H02J7/00714, H02J7/00716, H02J7/00718, H02J7/007182, H02J7/007184, and H02J7/007186.
All groups listed in this Warning should be considered in order to perform a complete search.
H02J7/087the charge cycle being terminated in response to non-electric parametersGroup H02J7/087 is no longer used for the classification of documents as of 2020-01-01.
The content of this group is being reclassified into groups H02J7/007188, H02J7/00719, H02J7/007192, and H02J7/007194.
All groups listed in this Warning should be considered in order to perform a complete search.
H02J2007/10using semiconductor devices onlyGroup H02J2007/10 is no longer used for the classification of documents as of 2020-01-01.
The content of this group is being reclassified into groups H02J7/007, H02J7/0071, H02J7/00711, H02J7/00712, H02J7/00714, H02J7/00716, H02J7/00718, H02J7/007182, H02J7/007184, H02J7/007186, H02J7/007188, H02J7/00719, H02J7/007192, and H02J7/007194.
All groups listed in this Warning should be considered in order to perform a complete search.
H02J7/12using magnetic devices having controllable degree of saturation, i.e. transductors H02J7/125in combination with discharge tubes or semiconductor devicesGroup H02J7/125 is no longer used for the classification of documents as of 2020-01-01.
The content of this group is being reclassified into groups H02J7/007, H02J7/0071, H02J7/00711, H02J7/00712, H02J7/00714, H02J7/00716, H02J7/00718, H02J7/007182, H02J7/007184, H02J7/007186, H02J7/007188, H02J7/00719, H02J7/007192, and H02J7/007194.
All groups listed in this Warning should be considered in order to perform a complete search.
H02J7/14for charging batteries from dynamo-electric generators driven at varying speed, e.g. on vehicle H02J7/1407on vehicles not being driven by a motor, e.g. bicycles H02J7/1415with a generator driven by a prime mover other than the motor of a vehicle H02J7/1423with multiple batteries H02J7/143with multiple generators H02J7/1438in combination with power supplies for loads other than batteries H02J7/1446in response to parameters of a vehicle H02J7/1461with safety or indicationg devicesGroup H02J7/1461 is no longer used for the classification of documents as of 2020-01-01.
The content of this group is being reclassified into groups H02J7/0029, H02J7/00302, H02J7/00304, H02J7/00306, H02J7/00308, H02J7/00309, H02J7/0047, H02J7/0048, H02J7/0049, and H02J7/005.
All groups listed in this Warning should be considered in order to perform a complete search.
H02J7/1469Regulation of the charging current or voltage otherwise than by variation of field H02J7/1476by mechanical action on the generator H02J7/1484by commutation of the output windings of the generator H02J7/1492by means of controlling devices between the generator output and the battery H02J7/16Regulation of the charging current or voltage by variation of field H02J7/163with special means for initiating or limiting the excitation current H02J7/166with safety or indicating devicesGroup H02J7/166 is no longer used for the classification of documents as of 2020-01-01.
The content of this group is being reclassified into groups H02J7/0029, H02J7/00302, H02J7/00304, H02J7/00306, H02J7/00308, H02J7/00309, H02J7/0047, H02J7/0048, H02J7/0049, and H02J7/005.
All groups listed in this Warning should be considered in order to perform a complete search.
H02J7/18due to variation of ohmic resistance in field circuit, using resistance switching in or out of circuit step by step H02J7/20due to variation of continuously variable ohmic resistor H02J7/22due to variation of make-to-break ratio of intermittently-operating contacts, e.g. using Tirrill regulator H02J7/225characterised by the mechanical construction H02J7/24using discharge tubes or semiconductor devices H02J7/243with on/off action H02J7/2434with pulse modulation H02J7/2437using thyristors or triacs as final control devices H02J7/26using magnetic devices with controllable degree of saturation H02J7/28using magnetic devices with controllable degree of saturation in combination with controlled discharge tube or controlled semiconductor device H02J7/30using armature-reaction-excited machines
H02J7/32for charging batteries from a charging set comprising a non-electric prime mover rotating at constant speed H02J7/34Parallel operation in networks using both storage and other dc sources, e.g. providing buffering H02J7/14 takes precedence H02J7/342The other DC source being a battery actively interacting with the first one, i.e. battery to battery charging with circuits for polarity protection H02J7/0034 H02J7/345using capacitors as storage or buffering devices H02J7/35with light sensitive cells H02J7/36Arrangements using end-cell switching
H02J9/00Circuit arrangements for emergency or stand-by power supply, e.g. for emergency lighting H02J9/002in which a reserve is maintained in an energy source by disconnecting non-critical loads, e.g. maintaining a reserve of charge in a vehicle battery for starting an engine H02J9/005using a power saving mode for copiers G03G15/5004 H02J9/007Detection of the absence of a load H02J9/02in which an auxiliary distribution system and its associated lamps are brought into service H02J9/04in which the distribution system is disconnected from the normal source and connected to a standby source H02J9/06with automatic change-over , e.g. UPS systems H02J9/061for DC powered loads H02J9/062for AC powered loads H02J9/063Common neutral, e.g. AC input neutral line connected to AC output neutral line and DC middle point H02J9/065for lighting purposes H02J9/066characterised by the use of dynamo-electric machines H02J9/08 takes precedence H02J9/067using multi-primary transformers, e.g. transformer having one primary for each AC energy source and a secondary for the loads H02J9/068Electronic means for switching from one power supply to another power supply, e.g. to avoid parallel connection H02J9/08requiring starting of a prime-mover H02J11/00Circuit arrangements for providing service supply to auxiliaries of stations in which electric power is generated, distributed or converted H02J13/00Circuit arrangements for providing remote indication of network conditions, e.g. an instantaneous record of the open or closed condition of each circuitbreaker in the networkCircuit arrangements for providing remote control of switching means in a power distribution network, e.g. switching in and out of current consumers by using a pulse code signal carried by the networkGroup H02J13/00 is incomplete pending reclassification of documents from groups H02J13/0003, H02J13/0006, H02J13/0013, H02J13/0079, and H02J13/0086.
Groups H02J13/00, H02J13/0003, H02J13/0006, H02J13/0013, H02J13/0079, and H02J13/0086 should be considered in order to perform a complete search.
H02J13/00001characterised by the display of information or by user interaction, e.g. supervisory control and data acquisition systems [SCADA] or graphical user interfaces [GUI]Group H02J13/00001 is incomplete pending reclassification of documents from groups H02J13/0003, H02J13/0006, H02J13/0079, H02J13/0086, H02J13/0093, and H02J13/0096.
All groups listed in this Warning should be considered in order to perform a complete search.
H02J13/00002characterised by monitoringGroup H02J13/00002 is incomplete pending reclassification of documents from groups H02J13/0003, H02J13/0006, H02J13/0079, H02J13/0086, H02J13/0093, and H02J13/0096.
All groups listed in this Warning should be considered in order to perform a complete search.
H02J13/00004characterised by the power network being locally controlledGroup H02J13/00004 is incomplete pending reclassification of documents from groups H02J13/0003, H02J13/0006, H02J13/0079, H02J13/0086, H02J13/0093, and H02J13/0096.
All groups listed in this Warning should be considered in order to perform a complete search.
H02J13/00006characterised by information or instructions transport means between the monitoring, controlling or managing units and monitored, controlled or operated power network element or electrical equipmentGroup H02J13/00006 is incomplete pending reclassification of documents from groups H02J13/0003, H02J13/0006, H02J13/0013, H02J13/0079, H02J13/0086, H02J13/0093, and H02J13/0096.
All groups listed in this Warning should be considered in order to perform a complete search.
H02J13/00007using the power network as support for the transmissionGroup H02J13/00007 is incomplete pending reclassification of documents from groups H02J13/0003, H02J13/0006, H02J13/0017, H02J13/0079, H02J13/0082, H02J13/0086, H02J13/0089, H02J13/0093, and H02J13/0096.
All groups listed in this Warning should be considered in order to perform a complete search.
H02J13/00009using pulsed signalsGroup H02J13/00009 is incomplete pending reclassification of documents from groups H02J13/0003, H02J13/0006, H02J13/0017, H02J13/0079, H02J13/0082, H02J13/0086, H02J13/0089, H02J13/0093, and H02J13/0096.
All groups listed in this Warning should be considered in order to perform a complete search.
H02J13/0001using modification of a parameter of the network power signalGroup H02J13/0001 is incomplete pending reclassification of documents from groups H02J13/0003, H02J13/0006, H02J13/0017, H02J13/0079, H02J13/0082, H02J13/0086, H02J13/0089, H02J13/0093, and H02J13/0096.
All groups listed in this Warning should be considered in order to perform a complete search.
H02J13/00012using an auxiliary transmission lineGroup H02J13/00012 is incomplete pending reclassification of documents from groups H02J13/0003, H02J13/0006, H02J13/0017, H02J13/0079, H02J13/0086, H02J13/0093, and H02J13/0096.
All groups listed in this Warning should be considered in order to perform a complete search.
H02J13/00014carrying signals having the network frequency or DC signalsGroup H02J13/00014 is incomplete pending reclassification of documents from groups H02J13/0003, H02J13/0006, H02J13/0017, H02J13/0079, H02J13/0086, H02J13/0093, and H02J13/0096.
All groups listed in this Warning should be considered in order to perform a complete search.
H02J13/00016using a wired telecommunication network or a data transmission busGroup H02J13/00016 is incomplete pending reclassification of documents from groups H02J13/0003, H02J13/0006, H02J13/0017, H02J13/0062, H02J13/0079, H02J13/0086, H02J13/0093, and H02J13/0096.
All groups listed in this Warning should be considered in order to perform a complete search.
H02J13/00017using optical fiberGroup H02J13/00017 is incomplete pending reclassification of documents from groups H02J13/0003, H02J13/0006, H02J13/0017, H02J13/0062, H02J13/0079, H02J13/0086, H02J13/0093, and H02J13/0096.
All groups listed in this Warning should be considered in order to perform a complete search.
H02J13/00018using phone linesGroup H02J13/00018 is incomplete pending reclassification of documents from groups H02J13/0003, H02J13/0006, H02J13/0017, H02J13/0079, H02J13/0086, H02J13/0093, and H02J13/0096.
All groups listed in this Warning should be considered in order to perform a complete search.
H02J13/00019using optical meansGroup H02J13/00019 is incomplete pending reclassification of documents from groups H02J13/0003, H02J13/0006, H02J13/0017, H02J13/0079, H02J13/0086, H02J13/0093, and H02J13/0096.
All groups listed in this Warning should be considered in order to perform a complete search.
H02J13/0002using ultrasonic meansGroup H02J13/0002 is incomplete pending reclassification of documents from groups H02J13/0003, H02J13/0006, H02J13/0017, H02J13/0079, H02J13/0086, H02J13/0093, and H02J13/0096.
All groups listed in this Warning should be considered in order to perform a complete search.
H02J13/00022using wireless data transmissionGroup H02J13/00022 is incomplete pending reclassification of documents from groups H02J13/0003, H02J13/0006, H02J13/0017, H02J13/0075, H02J13/0079, H02J13/0086, H02J13/0093, and H02J13/0096.
All groups listed in this Warning should be considered in order to perform a complete search.
H02J13/00024by means of mobile telephonyGroup H02J13/00024 is incomplete pending reclassification of documents from groups H02J13/0003, H02J13/0006, H02J13/0017, H02J13/0075, H02J13/0079, H02J13/0086, H02J13/0093, and H02J13/0096.
All groups listed in this Warning should be considered in order to perform a complete search.
H02J13/00026involving a local wireless network, e.g. Wi-Fi, ZigBee or BluetoothGroup H02J13/00026 is incomplete pending reclassification of documents from groups H02J13/0003, H02J13/0006, H02J13/0017, H02J13/0075, H02J13/0079, H02J13/0086, H02J13/0093, and H02J13/0096.
All groups listed in this Warning should be considered in order to perform a complete search.
H02J13/00028involving the use of Internet protocolsGroup H02J13/00028 is incomplete pending reclassification of documents from groups H02J13/0003, H02J13/0006, H02J13/0017, H02J13/0079, H02J13/0086, H02J13/0093, and H02J13/0096.
All groups listed in this Warning should be considered in order to perform a complete search.
H02J13/0003for DC networks Group H02J13/0003 is no longer used for the classification of documents as of 2020-01-01.
The content of this group is being reclassified into groups H02J1/00, H02J1/001, H02J1/002, H02J1/02, H02J1/04, H02J1/06, H02J1/08, H02J1/082, H02J1/084, H02J1/086, H02J1/10, H02J1/102, H02J1/106, H02J1/108, H02J1/109, H02J1/12, H02J1/122, H02J1/14, H02J1/16, H02J13/00, H02J13/00001, H02J13/00002, H02J13/00004, H02J13/00006, H02J13/00007, H02J13/00009, H02J13/0001, H02J13/00012, H02J13/00014, H02J13/00016, H02J13/00017, H02J13/00018, H02J13/00019, H02J13/0002, H02J13/00022, H02J13/00024, H02J13/00026, H02J13/00028, H02J13/00032, H02J13/00034, H02J13/00036, H02J13/0004, H02J13/0005, and H02J2213/10.
All groups listed in this Warning should be considered in order to perform a complete search.
H02J13/00032Systems characterised by the controlled or operated power network elements or equipment, the power network elements or equipment not otherwise provided for circuits specially adapted for remote switching of lighting via the power line H05B47/185Group H02J13/00032 is incomplete pending reclassification of documents from groups H02J13/0003, H02J13/0006, H02J13/0017, H02J13/0079, H02J13/0086, H02J13/0093, and H02J13/0096.
All groups listed in this Warning should be considered in order to perform a complete search.
H02J13/00034the elements or equipment being or involving an electric power substationGroup H02J13/00034 is incomplete pending reclassification of documents from groups H02J13/0003, H02J13/0006, H02J13/0017, H02J13/0079, H02J13/0086, H02J13/0093, and H02J13/0096.
All groups listed in this Warning should be considered in order to perform a complete search.
H02J13/00036the elements or equipment being or involving switches, relays or circuit breakers circuits for indication of single switches H01H9/167Group H02J13/00036 is incomplete pending reclassification of documents from groups H02J13/0003, H02J13/0006, H02J13/0017, H02J13/0079, H02J13/0086, H02J13/0093, and H02J13/0096.
All groups listed in this Warning should be considered in order to perform a complete search.
H02J13/0004involved in a protection systemGroup H02J13/0004 is incomplete pending reclassification of documents from groups H02J13/0003, H02J13/0006, H02J13/0017, H02J13/0079, H02J13/0086, H02J13/0093, and H02J13/0096.
All groups listed in this Warning should be considered in order to perform a complete search.
H02J13/0005the elements or equipment being or involving power plugs or socketsGroup H02J13/0005 is incomplete pending reclassification of documents from groups H02J13/0003, H02J13/0006, H02J13/0017, H02J13/0079, H02J13/0086, H02J13/0093, and H02J13/0096.
All groups listed in this Warning should be considered in order to perform a complete search.
H02J13/0006for single frequency AC networksGroup H02J13/0006 is no longer used for the classification of documents as of 2020-01-01.
The content of this group is being reclassified into groups H02J3/00, H02J3/0012, H02J3/00125, H02J3/002, H02J3/003, H02J3/004, H02J2203/10, H02J2203/20, H02J3/007, H02J3/0073, H02J3/0075, H02J3/008, H02J3/01, H02J3/02, H02J3/04, H02J3/06, H02J3/08, H02J3/10, H02J3/12, H02J3/14, H02J3/144, H02J3/16, H02J3/18, H02J3/1807, H02J3/1814, H02J3/1821, H02J3/1828, H02J3/1835, H02J3/1842, H02J3/185, H02J3/1857, H02J3/1864, H02J3/1871, H02J3/1878, H02J3/1885, H02J3/1892, H02J3/20, H02J3/22, H02J3/24, H02J3/241, H02J3/242, H02J3/26, H02J3/28, H02J3/30, H02J3/32, H02J3/322, H02J3/34, H02J3/36, H02J3/38, H02J3/381, H02J3/472, H02J3/388, H02J3/40, H02J3/42, H02J3/44, H02J3/46, H02J3/48, H02J3/50, H02J13/00, H02J13/00001, H02J13/00002, H02J13/00004, H02J13/00006, H02J13/00007, H02J13/00009, H02J13/0001, H02J13/00012, H02J13/00014, H02J13/00016, H02J13/00017, H02J13/00018, H02J13/00019, H02J13/0002, H02J13/00022, H02J13/00024, H02J13/00026, H02J13/00028, H02J13/00032, H02J13/00034, H02J13/00036, H02J13/0004, H02J13/0005, and H02J2213/10.
All groups listed in this Warning should be considered in order to perform a complete search.
H02J13/0013characterised by transmission structure between the control or monitoring unit and the controlled or monitored unitGroup H02J13/0013 is no longer used for the classification of documents as of 2020-01-01.
The content of this group is being reclassified into groups H02J13/00 and H02J13/00006.
Groups H02J13/0013, H02J13/00, and H02J13/00006 should be considered in order to perform a complete search.
H02J13/0017with direct transmission between the control or monitoring unit and the controlled or monitored unit Group H02J13/0017 is no longer used for the classification of documents as of 2020-01-01.
The content of this group is being reclassified into groups H02J13/00007, H02J13/00009, H02J13/0001, H02J13/00012, H02J13/00014, H02J13/00016, H02J13/00017, H02J13/00018, H02J13/00019, H02J13/0002, H02J13/00022, H02J13/00024, H02J13/00026, H02J13/00028, H02J13/00032, H02J13/00034, H02J13/00036, H02J13/0004, H02J13/0005, and H02J2213/10.
All groups listed in this Warning should be considered in order to perform a complete search.
H02J13/0062using a data transmission bus Group H02J13/0062 is no longer used for the classification of documents as of 2020-01-01.
The content of this group is being reclassified into groups H02J13/00016 and H02J13/00017.
Groups H02J13/0062, H02J13/00016, and H02J13/00017 should be considered in order to perform a complete search.
H02J13/0075using radio meansGroup H02J13/0075 is no longer used for the classification of documents as of 2020-01-01.
The content of this group is being reclassified into groups H02J13/00022, H02J13/00024, and H02J13/00026.
Groups H02J13/0075, H02J13/00022, H02J13/00024, and H02J13/00026 should be considered in order to perform a complete search.
H02J13/0079with transmission using an intermediate treatment level between the control or monitoring unit and the controlled or monitored unitGroup H02J13/0079 is no longer used for the classification of documents as of 2020-01-01.
The content of this group is being reclassified into groups H02J13/00, H02J13/00001, H02J13/00002, H02J13/00004, H02J13/00006, H02J13/00007, H02J13/00009, H02J13/0001, H02J13/00012, H02J13/00014, H02J13/00016, H02J13/00017, H02J13/00018, H02J13/00019, H02J13/0002, H02J13/00022, H02J13/00024, H02J13/00026, H02J13/00028, H02J13/00032, H02J13/00034, H02J13/00036, H02J13/0004, H02J13/0005, and H02J2213/10.
All groups listed in this Warning should be considered in order to perform a complete search.
H02J13/0082using the power network as transmission support Group H02J13/0082 is no longer used for the classification of documents as of 2020-01-01.
The content of this group is being reclassified into groups H02J2213/10, H02J13/00007, H02J13/00009, and H02J13/0001.
Groups H02J13/0082, H02J2213/10, H02J13/00007, H02J13/00009, and H02J13/0001 should be considered in order to perform a complete search.
H02J13/0086with transmission using plurality of intermediate treatment level between the control or monitoring unit and the controlled or monitored unitGroup H02J13/0086 is no longer used for the classification of documents as of 2020-01-01.
The content of this group is being reclassified into groups H02J13/00, H02J13/00001, H02J13/00002, H02J13/00004, H02J13/00006, H02J13/00007, H02J13/00009, H02J13/0001, H02J13/00012, H02J13/00014, H02J13/00016, H02J13/00017, H02J13/00018, H02J13/00019, H02J13/0002, H02J13/00022, H02J13/00024, H02J13/00026, H02J13/00028, H02J13/00032, H02J13/00034, H02J13/00036, H02J13/0004, H02J13/0005, and H02J2213/10.
All groups listed in this Warning should be considered in order to perform a complete search.
H02J13/0089using the power network as transmission supportGroup H02J13/0089 is no longer used for the classification of documents as of 2020-01-01.
The content of this group is being reclassified into groups H02J2213/10, H02J13/00007, H02J13/00009, and H02J13/0001.
Groups H02J13/0089, H02J2213/10, H02J13/00007, H02J13/00009, and H02J13/0001 should be considered in order to perform a complete search.
H02J13/0093for AC networks with plurality frequenciesGroup H02J13/0093 is no longer used for the classification of documents as of 2020-01-01.
The content of this group is being reclassified into groups H02J3/02, H02J13/00001, H02J13/00002, H02J13/00004, H02J13/00006, H02J13/00007, H02J13/00009, H02J13/0001, H02J13/00012, H02J13/00014, H02J13/00016, H02J13/00017, H02J13/00018, H02J13/00019, H02J13/0002, H02J13/00022, H02J13/00024, H02J13/00026, H02J13/00028, H02J13/00032, H02J13/00034, H02J13/00036, H02J13/0004, H02J13/0005, and H02J2213/10.
All groups listed in this Warning should be considered in order to perform a complete search.
H02J13/0096for networks combining AC and DC powerGroup H02J13/0096 is no longer used for the classification of documents as of 2020-01-01.
The content of this group is being reclassified into groups H02J3/02, H02J4/00, H02J13/00001, H02J13/00002, H02J13/00004, H02J13/00006, H02J13/00007, H02J13/00009, H02J13/0001, H02J13/00012, H02J13/00014, H02J13/00016, H02J13/00017, H02J13/00018, H02J13/00019, H02J13/0002, H02J13/00022, H02J13/00024, H02J13/00026, H02J13/00028, H02J13/00032, H02J13/00034, H02J13/00036, H02J13/0004, H02J13/0005, and H02J2213/10.
All groups listed in this Warning should be considered in order to perform a complete search.
H02J15/00Systems for storing electric energy mechanical systems therefor F01-F04; in chemical form H01MGroup H02J15/00 is impacted by reclassification into groups H02J15/007 and H02J15/008.
Groups H02J15/00, H02J15/007, and H02J15/008 should be considered in order to perform a complete search.
H02J15/003in the form of hydraulic energy H02J15/006in the form of pneumatic energy, e.g. compressed air energy storage [CAES] accumulators for supplying fluid under pressure F15B1/04 H02J15/007involving storage in the form of mechanical energy, e.g. fly-wheelsGroup H02J15/007 is incomplete pending reclassification of documents from group H02J15/00.
Groups H02J15/00 and H02J15/007 should be considered in order to perform a complete search.
H02J15/008using hydrogen as energy vectorGroup H02J15/008 is incomplete pending reclassification of documents from group H02J15/00.
Groups H02J15/00 and H02J15/008 should be considered in order to perform a complete search.
H02J50/00Circuit arrangements or systems for wireless supply or distribution of electric powerIn this main group, the specific types of wireless technology used for the power transmission are covered in groups H02J50/05-H02J50/30, while aspects relevant to the circuit arrangements or systems thereof are covered in groups H02J50/40-H02J50/90.Group H02J50/00 is impacted by reclassification into groups H02J50/001 and H02J50/005.
Groups H02J50/00, H02J50/001, and H02J50/005 should be considered in order to perform a complete search.
H02J50/001Energy harvesting or scavengingGroup H02J50/001 is incomplete pending reclassification of documents from groups H02J5/005, H02J7/025, and H02J50/00.
Groups H02J50/001, H02J5/005, H02J7/025, and H02J50/00 should be considered in order to perform a complete search.
H02J50/005Mechanical details of housing or structure aiming to accommodate the power transfer means, e.g. mechanical integration of coils, antennas or transducers into emitting or receiving devicesGroup H02J50/005 is incomplete pending reclassification of documents from groups H02J5/005, H02J7/025, and H02J50/00.
Groups H02J50/005, H02J5/005, H02J7/025, and H02J50/00 should be considered in order to perform a complete search.
H02J50/05using capacitive coupling H02J50/10using inductive couplingGroup H02J50/10 is incomplete pending reclassification of documents from groups H02J5/005 and H02J7/025.
Groups H02J5/005, H02J7/025, and H02J50/10 should be considered in order to perform a complete search.
H02J50/12of the resonant typeGroup H02J50/12 is incomplete pending reclassification of documents from groups H02J5/005 and H02J7/025.
Groups H02J5/005, H02J7/025, and H02J50/12 should be considered in order to perform a complete search.
H02J50/15using ultrasonic waves H02J50/20using microwaves or radio frequency waves H02J50/23characterised by the type of transmitting antennas, e.g. directional array antennas or Yagi antennas H02J50/27characterised by the type of receiving antennas, e.g. rectennas H02J50/30using light, e.g. lasersGroup H02J50/30 is incomplete pending reclassification of documents from groups H02J5/005 and H02J7/025.
Groups H02J5/005, H02J7/025, and H02J50/30 should be considered in order to perform a complete search.
H02J50/40using two or more transmitting or receiving devices H02J50/50 takes precedenceGroup H02J50/40 is incomplete pending reclassification of documents from groups H02J5/005 and H02J7/025.
Group H02J50/40 is also impacted by reclassification into group H02J50/402.
Groups H02J50/40, H02J5/005 and H02J7/025 and H02J50/402 should be considered in order to perform a complete search.
H02J50/402the two or more transmitting or the two or more receiving devices being integrated in the same unit, e.g. power mats with several coils or antennas with several sub-antennasGroup H02J50/402 is incomplete pending reclassification of documents from groups H02J5/005, H02J7/025, and H02J50/40.
Groups H02J50/402, H02J5/005, H02J7/025, and H02J50/40 should be considered in order to perform a complete search.
H02J50/50using additional energy repeaters between transmitting devices and receiving devicesGroup H02J50/50 is incomplete pending reclassification of documents from groups H02J5/005 and H02J7/025.
Group H02J50/50 is also impacted by reclassification into group H02J50/502.
Groups H02J50/50, H02J5/005 and H02J7/025 should be considered in order to perform a complete search.
H02J50/502the energy repeater being integrated together with the emitter or the receiverGroup H02J50/502 is incomplete pending reclassification of documents from groups H02J5/005, H02J7/025, and H02J50/50.
Groups H02J50/502, H02J5/005, H02J7/025, and H02J50/50 should be considered in order to perform a complete search.
H02J50/60responsive to the presence of foreign objects, e.g. detection of living beingsGroup H02J50/60 is incomplete pending reclassification of documents from groups H02J5/005 and H02J7/025.
Groups H02J5/005, H02J7/025, and H02J50/60 should be considered in order to perform a complete search.
H02J50/70involving the reduction of electric, magnetic or electromagnetic leakage fieldsGroup H02J50/70 is incomplete pending reclassification of documents from groups H02J5/005 and H02J7/025.
Groups H02J5/005, H02J7/025, and H02J50/70 should be considered in order to perform a complete search.
H02J50/80involving the exchange of data, concerning supply or distribution of electric power, between transmitting devices and receiving devicesGroup H02J50/80 is incomplete pending reclassification of documents from groups H02J5/005 and H02J7/025.
Groups H02J5/005, H02J7/025, and H02J50/80 should be considered in order to perform a complete search.
H02J50/90involving detection or optimisation of position, e.g. alignmentGroup H02J50/90 is incomplete pending reclassification of documents from groups H02J5/005 and H02J7/025.
Groups H02J5/005, H02J7/025, and H02J50/90 should be considered in order to perform a complete search.
H02J2203/00Indexing scheme relating to details of circuit arrangements for AC mains or AC distribution networks H02J2203/10Power transmission or distribution systems management focussing at grid-level, e.g. load flow analysis, node profile computation, meshed network optimisation, active network management or spinning reserve managementGroup H02J2203/10 is incomplete pending reclassification of documents from group H02J13/0006.
Groups H02J13/0006 and H02J2203/10 should be considered in order to perform a complete search.
H02J2203/20Simulating, e g planning, reliability check, modelling or computer assisted design [CAD]Group H02J2203/20 is incomplete pending reclassification of documents from group H02J13/0006.
Groups H02J13/0006 and H02J2203/20 should be considered in order to perform a complete search.
H02J2207/00Indexing scheme relating to details of circuit arrangements for charging or depolarising batteries or for supplying loads from batteries H02J2207/10Control circuit supply, e.g. means for supplying power to the control circuit H02J2207/20Charging or discharging characterised by the power electronics converterGroup H02J2207/20 is incomplete pending reclassification of documents from group H02J7/022.
Groups H02J7/022 and H02J2207/20 should be considered in order to perform a complete search.
H02J2207/30Charge provided using DC bus or data bus of a computer H02J2207/40adapted for charging from various sources, e.g. AC, DC or multivoltage H02J2207/50Charging of capacitors, supercapacitors, ultra-capacitors or double layer capacitors using capacitors as storage or buffering device in cooperation with batteries H02J7/345
H02J2213/00Indexing scheme relating to details of circuit arrangements for providing remote indication of network conditions of for circuit arrangements for providing remote control of switching means in a power distribution network H02J2213/10using simultaneously two or more different transmission meansGroup H02J2213/10 is incomplete pending reclassification of documents from groups H02J13/0003, H02J13/0006, H02J13/0017, H02J13/0079, H02J13/0082, H02J13/0086, H02J13/0089, H02J13/0093, and H02J13/0096.
All groups listed in this Warning should be considered in order to perform a complete search.
H02J2300/00Systems for supplying or distributing electric power characterised by decentralized, dispersed, or local generation H02J2300/10The dispersed energy generation being of fossil origin, e.g. diesel generators H02J2300/20The dispersed energy generation being of renewable originGroup H02J2300/20 is incomplete pending reclassification of documents from group H02J3/382.
Groups H02J3/382 and H02J2300/20 should be considered in order to perform a complete search.
H02J2300/22The renewable source being solar energyGroup H02J2300/22 is incomplete pending reclassification of documents from group H02J3/382.
Groups H02J3/382 and H02J2300/22 should be considered in order to perform a complete search.
H02J2300/24of photovoltaic originGroup H02J2300/24 is incomplete pending reclassification of documents from group H02J3/383.
Groups H02J3/383 and H02J2300/24 should be considered in order to perform a complete search.
H02J2300/26involving maximum power point tracking control for photovoltaic sources maximum power point systems in particular G05F1/67Group H02J2300/26 is incomplete pending reclassification of documents from group H02J3/385.
Groups H02J3/385 and H02J2300/26 should be considered in order to perform a complete search.
H02J2300/28The renewable source being wind energy wind motors F03DGroup H02J2300/28 is incomplete pending reclassification of documents from group H02J3/386.
Groups H02J3/386 and H02J2300/28 should be considered in order to perform a complete search.
H02J2300/30The power source being a fuel cellGroup H02J2300/30 is incomplete pending reclassification of documents from group H02J3/387.
Groups H02J3/387 and H02J2300/30 should be considered in order to perform a complete search.
H02J2300/40wherein a plurality of decentralised, dispersed or local energy generation technologies are operated simultaneously
H02J2310/00The network for supplying or distributing electric power characterised by its spatial reach or by the load H02J2310/10The network having a local or delimited stationary reach H02J2310/12The local stationary network supplying a household or a building H02J2310/14The load or loads being home appliances H02J2310/16The load or loads being an Information and Communication Technology [ICT] facility H02J2310/18The network being internal to a power source or plant H02J2310/20The network being internal to a load H02J2310/22The load being a portable electronic deviceGroup H02J2310/22 is incomplete pending reclassification of documents from group H02J7/0027.
Groups H02J7/0027 and H02J2310/22 should be considered in order to perform a complete search.
H02J2310/23The load being a medical device, a medical implant, or a life supporting device
H02J2310/40The network being an on-board power network, i.e. within a vehicleGroup H02J2310/40 is incomplete pending reclassification of documents from group H02J7/0027.
Groups H02J7/0027 and H02J2310/40 should be considered in order to perform a complete search.
H02J2310/42for ships or vesselsGroup H02J2310/42 is incomplete pending reclassification of documents from group H02J7/0027.
Groups H02J7/0027 and H02J2310/42 should be considered in order to perform a complete search.
H02J2310/44for aircraftsGroup H02J2310/44 is incomplete pending reclassification of documents from group H02J7/0027.
Groups H02J7/0027 and H02J2310/44 should be considered in order to perform a complete search.
H02J2310/46for ICE-powered road vehiclesGroup H02J2310/46 is incomplete pending reclassification of documents from group H02J7/0027.
Groups H02J7/0027 and H02J2310/46 should be considered in order to perform a complete search.
H02J2310/48for electric vehicles [EV] or hybrid vehicles [HEV]Group H02J2310/48 is incomplete pending reclassification of documents from group H02J7/0027.
Groups H02J7/0027 and H02J2310/48 should be considered in order to perform a complete search.
H02J2310/50for selectively controlling the operation of the loads H02J2310/52The controlling of the operation of the load not being the total disconnection of the load, i.e. entering a degraded mode or in current limitation H02J2310/54according to a pre-established time schedule H02J2310/56characterised by the condition upon which the selective controlling is based H02J2310/58The condition being electrical H02J2310/60Limiting power consumption in the network or in one section of the network, e.g. load shedding or peak shaving H02J2310/62The condition being non-electrical, e.g. temperature H02J2310/64The condition being economic, e.g. tariff based load management H02J2310/66one of the loads acting as master and the other or others acting as slaves H02J2310/70Load identification